Flexible Dialing
Flexible Dialing permits the user to custom configure the digit length and the access codes for zones and paging
zone groups.
The digit length for Flexible Dialing can be set to 2, 3, 4 or 5 digits. When Flexible Dialing is enabled, zones and paging
zone groups are the same digit length and no * is used for accessing zone groups. Duplicate Flexible Dialing numbers
are not permitted.
Note: The digit length cannot be changed unless the user-programmed access codes have been cleared first.
When Flexible Dialing is enabled, a zone or paging zone group cannot be accessed until a Flexible Number has been
assigned to it.
When Flexible Dialing is disabled, the unit uses the default access codes for zones and paging zone groups
(01 through 12 for zones and *01 through *24 for paging zone groups). Disabling Flexible Dialing will not clear any
user-programmed access codes or the digit length setting. Flexible Dialing does not need to be enabled to program
the digit length or the new access codes for zones and paging zone groups. However, the new access codes are
functional only in Run mode and cannot be accessed in Program mode. When programming paging zone groups, the
default zone groups (*01 through *24) must be used.
To program the UTI312 system for Flexible Dialing, follow these instructions:
1. Use the table below to list and cross-reference the new Flexible Dialing Plan numbers before programming.
2. If this is the first time this feature has been programmed, then begin by setting the digit length (codes 062-065).
If this is not the first time this feature has been programmed, then begin by clearing all user-programmed access
codes (code 900#) and then set the digit length.
3. Dial the Feature Code (codes 101-224) and then the desired Flexible Dialing Number for that particular zone
or paging zone group.
4. Press the [#] key to store the programming data. If you don’t dial the [#] key, then the data is not stored.
A double beep will sound to confirm the entry.
5. When finished programming all of the Flexible Dialing Numbers for the zones and the paging zone groups,
enable Flexible Dialing (code 061).
6. Once you have finished all programming, you must first hang up the programming phone and then place the
Program/Run switch in the Run position. The green LED will go out.
Paging Zone
Groups
Flexible Dialing
#
Paging Zone
Groups
Flexible Dialing
#
Zone Group 1 Zone Group 13
Zone Group 2 Zone Group 14
Zone Group 3 Zone Group 15
Zone Group 4 Zone Group 16
Zone Group 5 Zone Group 17
Zone Group 6 Zone Group 18
Zone Group 7 Zone Group 19
Zone Group 8 Zone Group 20
Zone Group 9 Zone Group 21
Zone Group 10 Zone Group 22
Zone Group 11 Zone Group 23
Zone Group 12 Zone Group 24
Flexible Dialing Reference Chart
Zones
Flexible Dialing
#
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
Zone 9
Zone 10
Zone 11
Zone 12
Vista de pagina 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 31 32

Comentarios a estos manuales

Sin comentarios

Cypress Semiconductor Perform CY7C1380D Handbücher

Bedienungsanleitungen und Benutzerhandbücher für Nein Cypress Semiconductor Perform CY7C1380D.
Wir stellen 2 PDF-Handbücher Cypress Semiconductor Perform CY7C1380D zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Spezifikationen, Bedienungsanleitung






Weitere Produkte und Handbücher für Nein Cypress Semiconductor

Modelle Dokumententyp
CY7C028V Bedienungsanleitung   Data-Acquisition System Using Embedded Linux, 7 Seiten
CY8C21234 Bedienungsanleitung   CY8C21234/CY8C21334/CY8C21434/CY8C21534, 45 Seiten
CY7C1364C Bedienungsanleitung   256K x 36/256K x 32/512K x 18 Pipelined SRAM, 31 Seiten
CY8C21234 Datenblatt   Cypress Semiconductor CY8C21234 Datasheet, 53 Seiten
CY7C1527AV18 Bedienungsanleitung   CY7C1516AV18/CY7C1527AV18/CY7C1518AV18, 30 Seiten
Perform STK12C68 Bedienungsanleitung   STK12C68 64 Kbit (8K x 8) AutoStore nvSRAM, 22 Seiten
CY8C24894 Bedienungsanleitung   CY3240 USB-I2C Bridge Kit, 64 Seiten
STK11C68-5 Bedienungsanleitung   STK11C68, STK11C68-5 (SMD5962-92324), 64 [en] , 17 Seiten
Perform CY7C1513KV18 Datenblatt   Cypress Semiconductor Perform CY7C1513KV18 Datasheet, 35 Seiten
STK14C88-3 Bedienungsanleitung   STK14C88-3 256 Kbit (32K x 8) AutoStore nvSRAM, 17 Seiten
STK16C88 Bedienungsanleitung   STK11C68-L45I - Datasheet.Directory, 17 Seiten
Perform CY7C1356C Bedienungsanleitung   256Kx36/512Kx18 Pipelined SRAM with NoBL™ Architecture, 26 Seiten
CY7C68301C Bedienungsanleitung   datasheet: pdf, 42 Seiten
STK12C68-5 Bedienungsanleitung   Cypress Semiconductor STK12C68-5C35M datasheet: pdf, 18 Seiten
CY7C1380FV25 Bedienungsanleitung   18-Mbit (512K x 36/1M x 18), 29 Seiten
CY7C1516KV18 Datenblatt   Cypress Semiconductor CY7C1516KV18 Datasheet, 30 Seiten
CY7C1440AV33 Bedienungsanleitung   Cypress Semiconductor CY7C1440AV33-167AXC, 31 Seiten
SL811HS Bedienungsanleitung   Interfacing an External Processor to the SL811HS/S, 4 Seiten
CY7C1515JV18 Bedienungsanleitung   CY7C15(11,13,15,26)JV18 - Digi-Key, 27 Seiten
CY7C1447AV33 Bedienungsanleitung   Cypress Semiconductor CY7C1441AV33-133AXI [en] , 31 Seiten